Application
Guide # |
Application Guide Title |
Date Code |
Author |
|
AG89-01 |
Creating Nomographs Using the SEL-PROFILE Transmission Line Fault Analysis Program |
890000 |
|
|
AG91-01 |
SEL-121F Application Ideas |
910000 |
Jeff Roberts |
|
AG91-02 |
SEL-121G Application Guide: Programmable Logic Masks Provide Ultimate Flexibility in Scheme Designs |
910000 |
Ed Schweitzer |
|
AG92-01 |
SEL-251 Distribution Relay Reclosing Operation |
920000 |
Mark Feltis |
|
AG92-02 |
SEL-251/251C Distribution Relay Application Guide |
921015 |
Karl Zimmerman |
|
AG92-03 |
Faster Distribution Bus Tripping with the SEL-251/251C Relays |
921123 |
Mark Feltis |
|
AG93-01 |
Maximum Torque Angle Application Guide |
930000 |
Jeff Roberts |
|
AG93-02 |
SEL-251/151 Command Characteristics |
930406 |
David Wood |
|
AG93-03 |
REJO Application Guide |
970128 |
Jeff Roberts |
|
AG93-04 |
SEL-LFL Fault Locating and Experience |
930415 |
Tim Tibbals |
|
AG93-05 |
Worldport 2400 Modem Modification |
930628 |
|
|
AG93-06 |
Applying the SEL-321 Relay to Directional Comparison Blocking (DCB) Schemes |
930830 |
Jeff Roberts |
|
AG93-07 |
Reclosing Two Breakers with the SEL-251 Distribution Relay |
931012 |
Mark Feltis,
Dean Hardister |
|
AG93-08 |
SEL-AMS Technical Description |
960419 |
David Wood |
|
AG93-09 |
Testing Frequency Shift Carrier From a Single End Using the SEL-321 Relay |
960426 |
Karl Zimmerman |
|
AG93-10 |
SEL-321 Relay Load-Encroachment Function Setting Guidelines |
960523 |
John Kumm |
|
AG94-01 |
SEL-321 Zone 1 Extension Logic Description |
960626 |
Jeff Roberts |
|
AG94-02 |
SEL-221F/121F Fast Meter Command Processing |
940308 |
Tim Tibbals |
|
AG94-03 |
SEL Distributed Port Switch Protocol (LMD) |
970128 |
Tim Tibbals |
|
AG94-04 |
Applying SEL-501 Relay to Delta-Wye Transformer Bank Overcurrent Protection |
940621 |
Mark Feltis,
John Kumm |
|
AG94-05 |
Multiple Reclosing Functions in the SEL-321 Relay Using SELOGIC® Control Equations |
990610 |
Joe Mooney |
|
AG94-06 |
Worldport 9600 Modem |
940831 |
|
|
AG94-07 |
SEL-267D Standard and Extended Fast Meter Command Processing |
940909 |
Tim Tibbals |
|
AG94-08 |
SEL-251 Delta Versions Fast Meter Command Processing |
940915 |
Tim Tibbals |
|
AG94-09 |
SEL-221B/121B, SEL-221C/121C, SEL-221G/121G, SEL-221H/121H, SEL-221S/121S, SEL-121-10, SEL-2PG10/PG10, SEL-321-1 Fast Meter Command Processing |
960531 |
Tim Tibbals |
|
AG94-10 |
Applying SEL-501 Relay for Feeder Relay Backup Protection |
940929 |
Mark Feltis,
John Kumm |
|
AG94-11 |
Applying SEL-501 Relay for Fast Bus Trip and Simple Bus Breaker Failure Protection |
940929 |
Mark Feltis,
John Kumm |
|
AG94-12 |
SEL-251C/151C Standard and Extended Fast Meter Command Processing |
941007 |
Tim Tibbals |
|
AG94-13 |
Applying SEL-501 Relay for Ground Overcurrent Protection Using a Core-Balance CT |
941121 |
Mark Feltis,
John Kumm |
|
AG94-14 |
SEL-221G-3/SEL-321 Relay Setting Equivalency Sheet |
941228 |
John Kumm |
|
AG94-15 |
SEL-221G-5/SEL-321 Relay Setting Equivalency Sheet |
20000317 |
John Kumm |
|
AG94-16 |
SEL-221H/SEL-321 Relay Setting Equivalency Sheet |
941228 |
John Kumm |
|
AG95-01 |
SEL-221F/SEL-321 Relay Setting Equivalency Sheet |
20000317 |
John Kumm |
|
AG95-02 |
SEL-251/151 Standard and Extended Fast Meter Command Processing |
950120 |
Tim Tibbals |
|
AG95-03 |
SEL-321-1 Compressed ASCII Commands |
970228 |
Tim Tibbals |
|
AG95-04 |
Compressed ASCII Commands |
20030425
|
Tim Tibbals |
|
AG95-05 |
See AG96-05 and AG96-06 |
950829 |
Tim Tibbals |
|
AG95-06 |
SEL-321-1 Fast Operate Command Processing |
950208 |
Tim Tibbals |
|
AG95-07 |
Complete Transformer Protection Schemes Using the SEL-587 and SEL-501 Relays |
950313 |
Ed Schweitzer,
Jeff Roberts |
|
AG95-08 |
Select the Best Reclosing Method for Your Application (SEL-321 with Internal SEL-279/SEL-279H Reclosers) |
950522 |
Ed Schweitzer,
Jeff Roberts |
|
AG95-09 |
Shunt Capacitor Bank Protection Schemes Using the SEL-287V/501 and SEL-587/501 Relays |
950509 |
Ed Schweitzer,
Jeff Roberts |
|
AG95-10 |
Configuration and Fast Meter Messages |
20050121
|
Tim Tibbals,
David Wood |
|
AG95-11 |
SEL-321-1 Configuration and Fast Meter Messages |
20030425
|
Tim Tibbals |
|
AG95-12 |
SEL-587 Fast Operate Command Processing |
951128 |
Tim Tibbals |
|
AG95-13 |
SEL-587 Compressed ASCII Commands |
950922 |
Tim Tibbals |
|
AG95-14 |
SEL-587 Configuration and Fast Meter Messages |
951205 |
Tim Tibbals |
|
AG95-15 |
OBSOLETE - SEE AG96-08 |
950501 |
Jeff Roberts,
Armando Guzman |
|
AG95-16 |
SEL-251C Relay - 21P Phase Impedance Element |
950721 |
Ken Behrendt |
|
AG95-17 |
SEL-321 Relay Breaker Failure Protection |
951011 |
Karl Zimmerman |
|
AG95-18 |
Protecting Three Single-Phase Transformers Connected Delta-Wye with Cts Inside the Delta - SEL-587 Relay |
20031105 |
Larry Gross,
Armando Guzman |
|
AG95-19 |
Applying the SEL-279H Relay to Single Breaker Transmission Lines |
951011 |
Karl Zimmerman |
|
AG95-21 |
SEL-2020 Communication with Selected "Other IEDs" |
990514 |
Larry Gross,
Mark Weber |
|
AG95-23 |
Multiple Automatic Dial-Out Using the SEL-2020 (A "Job Done" Example) |
950526 |
Tim Tibbals,
Larry Gross |
|
AG95-25 |
Multiple SEL-2020 Operation |
20040511
|
David C. Wood |
|
AG95-26 |
Detecting High-Side Fuse Operations Using an SEL-251 Relay |
950926 |
Ed Schweitzer,
John J. Kumm |
|
AG95-29 |
Applying the SEL-321 Relay to Permissive Overreaching Transfer Trip (POTT) Schemes |
20050805
|
Armando Guzman,
Jeff Roberts,
Karl Zimmerman |
|
AG95-30 |
SEL-2020 Communications Processor and SEL-PRTU Comparison |
970611 |
Larry Gross |
|
AG95-31 |
Using the SEL-2020 to Implement a Low-Resolution Sequence-of-Events Recorder |
961119 |
John J. Kumm |
|
AG95-32 |
Using the SEL-501 Relay to Provide Switch-Onto-Fault Protection and Overcurrent Supervision in Existing Protection Schemes |
951205 |
John J. Kumm |
|
AG95-33 |
Applying SEL-501 Motor Protection with Self-Balancing Differential |
951212 |
Stan Zocholl |
|
AG96-02 |
SEL-501 Configuration and Fast Meter Messages |
960531 |
Tim Tibbals |
|
AG96-03 |
SEL-2020 Communications Processor Response Time for Data Acquisition and Control |
961205 |
David Wood |
|
AG96-04 |
Applying SEL-501 Relays for Generator Negative-Sequence I2T Protection |
960311 |
Stan Zocholl |
|
AG96-05 |
SEL-251 Series Fast Operate Command Processing |
960513 |
Tim Tibbals |
|
AG96-06 |
Fast Operate Command Processing: SEL-267D-3 |
960513 |
Tim Tibbals |
|
AG96-07 |
SEL-501-1 Configuration and Fast Meter Messages |
960531 |
Tim Tibbals,
Jian Chen |
|
AG96-08 |
Making Trip Circuit Monitor Logic with SELOGIC® Control Equations |
961031 |
Jeff Roberts,
Armando Guzman,
Larry Gross |
|
AG96-09 |
Protecting ±30° and ±150° Delta-Wye Transformers with the SEL-587 Relay |
970530 |
Larry Gross |
|
AG96-10 |
Using the SEL-587 Relay in a Machine Split-Phase Differential Protection Application |
20051115 |
John J. Kumm |
|
AG96-11 |
Using SEL Relays To Provide Primary Or Backup Bus Protection |
20001116 |
John J. Kumm |
|
AG96-12 |
Improve Security For Carrier Holes On DCB Schemes Using SEL Distance Relays |
970812 |
Karl Zimmerman |
|
AG96-13 |
Applying Mirrored Bits Communications to a Permissive Overreaching Transfer Trip (POTT) Scheme |
20020327 |
Ken Behrendt |
|
AG96-14 |
Implementation of a New Communication-Aided Tripping Scheme Using the SEL-321 Relay Mirrored Bit Function |
961121 |
John J. Kumm |
|
AG96-15 |
SEL-2020 Daylight Savings Time Change |
961002 |
Larry Gross |
|
AG96-16 |
Applying SEL Distance Relays on Lines with Power Transformers or Open Delta VTs |
961231 |
Karl Zimmerman |
|
AG96-17 |
Three Terminal Line Protection Using SEL-321-1 Relays with Mirrored Bits Communication |
20020401 |
Ken Behrendt |
|
AG96-18 |
A Breaker Simulator in the SEL-321 Relay for Three-Pole Tripping Application |
961105 |
Larry Gross |
|
AG96-19 |
Applying the SEL-321 Relay to Directional Comparison Unblocking (DCUB) Schemes |
961115 |
Dean Hardister |
|
AG96-20 |
Applying SEL-501 Relay Motor Protection |
20070517 |
Stanley E. Zocholl |
|
AG97-01 |
SEL-279H-2 Relay Application for Two Breakers |
970115 |
Karl Zimmerman,
Emery Perry |
|
AG97-02 |
Providing Automated Primary/Alternate Source on Distribution Feeders |
970115 |
Karl Zimmerman,
Jeff Roberts |
|
AG97-03 |
SEL-321-2 Relay Compressed ASCII Commands |
970128 |
Tim Tibbals |
|
AG97-04 |
Using the SEL-321 Relay and SEL-221G Relay as Primary and Backup Transmission Protection |
970207 |
Joe B. Mooney,
John J. Kumm |
|
AG97-05 |
Improve POTT Scheme Security by Adding Blocking to a Weak Third Terminal |
970207 |
John J. Kumm |
|
AG97-06 |
Using SELOGIC® Control Equations to Replace a Sudden Pressure Auxiliary Relay |
970324 |
David Costello |
|
AG97-07 |
Three Terminal POTT Protection Using the SEL-321 Relay |
970502 |
John J. Kumm |
|
AG97-08 |
Single-Pole/Three-Pole Autoreclose Function for Single Breaker Applications in the SEL-321 Relay Using SELOGIC® Control Equations |
980609 |
Joe Mooney |
|
AG97-09 |
SEL-2020 Communication with GEC Alsthom Courier Language Based Relays |
970408 |
David Dolezilek |
|
AG97-10 |
SEL-2020 Communication with General Electric GE-Link Language Based Relays |
970515 |
David Dolezilek |
|
AG97-11 |
Detecting High-Side Fuse Operations Using an SEL-351 Relay |
970513 |
Edmund O. Schweitzer, III,
John J. Kumm |
|
AG97-12 |
Using SEL-587 Relay for Protection of Power Transformer with One Zig-Zag Connection |
970523 |
Shaojun Chen,
Armando Guzman,
Steve Turner |
|
AG97-13 |
SEL-321-5 Relay Out-of-Step Logic |
20041206 |
DaqingHou,
Shaojun Chen,
Steve Turner |
|
AG97-14 |
Applying the SEL-351 Relay Synchro-Check Function With Phase-to-Phase Connected Synchronizing Potentials |
20011220 |
Ken Behrendt |
|
AG97-15 |
Using SELOGIC® Control Equations in the SEL-551 and SEL-351 to Implement a Breaker Simulator for Testing |
970821 |
David Costello |
|
AG97-17 |
Applying the SEL-221F Relay Synchro-Check Function with Phase-to-Phase Connected Synchronizing Potentials |
970909 |
Ken Behrendt |
|
AG97-18 |
Using SELOGIC® Control Equations to Provide Separate Trip Coil Monitor (TCM) Alarm Outputs in the SEL-321 Relay When Applied to Two-Breaker Line Terminals |
970909 |
Bill Fleming |
|
AG97-19 |
Using the SEL-321 Relay and SEL-221F Relay for Primary and Backup Transmission Protection |
970909 |
Joseph B. Mooney,
John J. Kumm |
|
AG97-21 |
Using the Sel-352 Relay to Avoid Generator and System Damage Due to a Slow Synchronizing Breaker |
971014 |
Larry Gross,
Mike Maxwell |
|
AG97-22 |
Applying the SEl-2885 in an Inexpensive Multidrop Communication Circuit |
971219 |
Emery Perry,
Ken Behrendt |
|
AG97-23 |
SEL-9501 Contact Arc Suppressor Application Guidelines |
20010104 |
Timothy Tibbals,
Tony Lee,
Randy Norheim |
|
AG98-01 |
Using the SEL-2020 to Monitor Critical Alarm Points and Provide Selective Paging |
980129 |
Jeff Gregory |
|
AG98-02 |
Unit Protection Scheme for the SEL-321-5 Relay |
980401 |
Steve Turner |
|
AG98-05 |
Automated UPS Battery Monitoring Using an SEL-351 Relay |
980306 |
Mike Maxwell |
|
AG98-06 |
SEL-351's and SEL-351R's to Provide Automated Load Restoration for Distribution Feeders |
980716 |
Karl Zimmerman,
Jeff Roberts,
David Dolezilek |
|
AG98-07 |
Implementing a Breaker Failure Function in the SEL-351 Relay |
991221 |
Bill Fleming |
|
AG98-08 |
Momentary Change Detection the SEL-351 Relay |
980427 |
Bob Morris,
Bill Fleming |
|
AG98-09 |
High Impedance Differential Protection Using Overcurrent Relays |
20010621 |
Rick Turner, Stan Zocholl |
|
AG98-10 |
Sensitive Earth Fault Protection for High-Impedance Earthed Distribution Systems Using the SEL-351 Relay |
980716 |
Rick Turner |
|
AG98-11 |
Testing the SEL-321-1 Relay-to-Relay Digital Logic Communication Time Delay |
980820 |
Ken Behrendt |
|
AG98-12 |
SEL-251 Relay Trip Seal-In |
980820 |
Dean Hardister |
|
AG98-13 |
Using an External Relay Setting Group Selector Switch with the SEL-351 Relay |
980820 |
Dean Hardister,
Jeff Gregory |
|
AG98-14 |
SEL-2020/2030 Communications With Quantum Digital Interface Protocol Based Meters |
981106 |
Mark Weber |
|
AG98-15 |
Creating a Phase Current Unbalance Alarm/Supervision Function in the SEL-351 Relay |
981223 |
Bill Fleming |
|
AG99-01 |
Using Contact Inputs to Detect DC Grounds |
990219 |
Karl Zimmerman |
|
AG99-02 |
SEL-351R Sensitive Ground Directional Elements |
990401 |
Ralph Folkers |
|
AG99-03 |
Flexible Transmission Line Reclosing and Breaker Failure With the SEL-351 Relay |
990909 |
Jeff Gregory |
|
AG99-04 |
Unsolicited Sequential Events Recorder |
990826 |
Tim Tibbals |
|
AG99-05 |
SEL-351 Relay Staged Capacitor Bank Control |
990803 |
Mike Collum |
|
AG99-06 |
SEL-701 Motor Protection Relay Modbus Communication |
990823 |
Darold Woodward |
|
AG99-07 |
Bus Protection Using a Four-Winding Low-Impedance Percentage Differential Relay |
20001023 |
Dave Costello
Stan Zocholl |
|
AG99-08 |
Applying the SEL-387-5 Relay Combined Overcurrent Elements |
991008 |
George E. Alexander,
Subhash Patel |
|
AG99-09 |
Cold Load Pickup Scheme Using the SEL-351 Relay |
991129 |
Dean Hardister |
|
AG99-10 |
Change Logic in SEL-351R Recloser Control for Motor-Operated Reclosers |
991130 |
Mark Feltis |
|
AG99-11 |
Programming Front-Panel Operator Controls in the SEL-351R Recloser Control |
991223 |
Dean Hardister, Mark Feltis |
|
AG2000-01 |
Determining the Correct TRCON Setting in the SEL-587 Relay When Applied to Delta-Wye Power Transformers |
20000209 |
David Costello,
Jeff Gregory |
|
AG2000-02 |
MIRRORED BITS® Communications with Spread Spectrum Radios |
|
David Costell,
Ken Fodero |
|
AG2000-03 |
Breaker Failure Scheme Provides Fast Clearing for Phase Faults and Standard Clearing for Ground Faults Using the SEL-352 Relay |
20000630 |
Jim Mack |
|
AG2000-04 |
Applying the SEL-352 Relay for Automatic Throw-Over Control of a Bus Tie and Incoming Circuit Breakers |
20000616 |
Shaojun Chen,
Scott Anderson |
|
AG2000-05 |
Improvements to the Loss-of-Potential (LOP) Function in the SEL-321 |
20000927 |
Jeff Roberts,
Ralph Folkers |
|
AG2000-06 |
Making SEL-351R Recloser Controls Talk
Supporting Files
|
20000824 |
Mike Collum |
|
AG2000-07 |
Connection and Configuration of SEL-2030 and SEL-2600 to Obtain Measured Ambient and Top-Oil Temperatures for SEL-387-6 Relay Thermal Element |
20050819 |
John Foertsch,
Bill Tyska |
|
AG2000-08 |
Applying the SEL-5040 Power System Report Manager |
20040604 |
Tim Tibbals
Mark Weber |
|
AG2000-09 |
Use SEL-321 and SEL-311 Relays Where Two Different Systems Are Required for Primary and Backup Protection |
20001017 |
Brian Lewandowski,
Joeseph B. Mooney,
Roy E. Moxley, P.E. |
|
AG2000-10 |
SEL-351S Data Acquisition and Control via Distributed Network Protocol (DNP) (A JOB DONE Example) |
20001206 |
Mike McKoy
|
|
AG2000-11 |
Applying the SEL-321 Relay on Series-Compensated Systems |
20001109 |
Joseph B. Mooney,
George E. Alexander |
|
AG2000-12 |
Applying the SEL-311C Relay on Three Terminal Lines |
20001113 |
George E. Alexander
|
|
AG2000-13 |
Installing, Using, and Troubleshooting SEL-5010 Relay Assistant |
20070423 |
David Nieuwsma, David Prestwich
|
|
AG2000-14 |
Multiple Trip Outputs for SEL-351 and SEL-551 Relays |
20001127 |
Dean Hardister
|
|
AG2000-15 |
Detecting Remote Fault and Circuit Breaker Failure Transfer Tripping in the SEL-351-2 Relay |
20010219 |
Shaojun Chen, Steve Turner, and Bai-Lin Qin |
|
AG2000-16 |
Underfrequency Load Shedding With the SEL-387E Relay |
20001220 |
Mirek Wronski |
|
AG2000-17 |
Voltage Control Element for the SEL-387E Relay |
20001220 |
Mirek Wronski |
|
AG2000-18 |
Grounded Shunt Capacitor Bank Protection Scheme Using SEL-287V and SEL-352 Relays |
20001221 |
Mirek Wronski |
|
AG2001-01 |
Fault Location and Fault Type Data Retrieval Using an SEL-2020/2030 Communications Processor (A JOB DONE Example) |
20010219 |
Michael J. Dood, P.E. |
|
AG2001-02 |
Setting the SEL-701 Motor Relay Thermal Element Using the Rating Method |
20010208 |
Jon Steinmetz |
|
AG2001-03 |
Installing and Servicing Connectors for Connectorized® Relays |
20010409 |
Jerry Hein |
AG2001-04 |
Using the SEL-351 Relay Synch-Check Element with Dissimilar Voltage Magnitudes on the Polarizing and Synchronizing Inputs |
20010420 |
Bill Fleming |
|
AG2001-05 |
Using Passwords to Secure Relays, Controllers, and SCADA Systems From Unauthorized Access |
20010517 |
Paul Oman |
|
AG2001-06 |
Avoiding Magnetic Induction Issues in Communication Cabling
|
20010703 |
Jeff Roberts, Mark Weber
|
|
AG2001-07 |
Using the SEL-311 Relay Synch-Check Element With Dissimilar Voltage Magnitudes on the Polarizing and Synchronizing Inputs |
20010522 |
Bill Fleming |
|
AG2001-08 |
Setting and Using Secure Dial-Back Modems With SEL Relays and Communications Processors |
20010529 |
Paul Oman |
|
AG2001-09 |
Applying the SEL-701-1 Monitor to Control Cooling Fans |
20010815 |
Subhash C. Patel and Angelo D'Aversa |
|
AG2001-10 |
Low-Cost Authentication Devices for Secure Modem and Network Connections |
20020124 |
Paul Oman |
|
AG2001-11 |
Telnet and FTP With the SEL-2701 Ethernet Processor |
20061120 |
Mike McKoy |
|
AG2001-12 |
Implementing MIRRORED BITS Technology Over Various Communications Media |
20070703 |
Ken Behrendt and Ken Fodero |
|
AG2001-13 |
Remote Disabling of the 87L Element in the SEL-311L Relay |
20050606 |
George E. Alexander |
|
AG2001-14 |
Implementing Breaker Failure Protection and Transfer Tripping With the SEL-311L Relay |
20011016 |
David Costello |
|
AG2002-01 |
Trafficwerks SEL Fast Message I/O Server Configuration |
20050419 |
Michael Boughman |
| AG2002-02 |
Compensate for Constant Phase Angle Difference in Synchronism Check With the SEL-351 Relay Family |
20020327 |
Mark Feltis |
| AG2002-03 |
Serial Communications Between PCs and SEL Microprocessor-Based Products |
20020402 |
Emery Perry, George Alexander, and Ken Behrendt |
|
AG2002-04 |
Setting an SEL-421-1 Relay to Obtain SEL-287V-0 Relay Functions
Supporting Files
|
20030425
|
Henry Nurse, Mirek Wronski |
|
AG2002-05 |
Securing SEL Ethernet Products with VPN Technology
|
20020711 |
Allen Risley, Chad Marlow, Paul Oman, Dave Dolezilek |
|
AG2002-06 |
Applying the SEL-351 Relay to an Ungrounded System
|
20020910 |
Normann Fischer, Mark Feltis |
|
AG2002-07 |
SEL-7000 Integrated Substation Control, Automation, Monitoring, and Protection System
|
20040317 |
Darold Woodward, Tim Tibbals |
| AG2002-08 |
Using SEL-421 Relay Synchrophasors in Basic Applications |
20030129 |
Chris Anderson, Brian Fearn, Armando Guzman, and Roy Moxley |
| AG2002-09 |