Literature Careers Products Services Contact Home Home
Calendar of Events > I-44
SEL I-44 Relay Conference

 

Branson, Missouri
August 26–28, 2008

 

 

August 26–28, 2008 - Branson, Missouri

The 12th annual SEL I-44 Relay Conference will focus on product application, testing, and commissioning through technical presentations and hands-on training.

 

We hope you can take advantage of this opportunity. Space is limited!

 

Register Today!

 

Cost:

$150 per person for the 2 1/2 day event. Lunch is provided on Tuesday and Wednesday, and refreshments and continental breakfast will be provided all days. Pay by purchase order or credit card no later than August 1, 2008. Registrations cancelled after August 13 will be charged a $50 cancellation fee.

 

Time:

Tuesday, August 26 — 7:30 a.m. to 4:00 p.m. (7:00 a.m. registration)
Wednesday, August 27 — 7:30 a.m. to 4:00 p.m.
Thursday, August 28 — 7:30 a.m. to 11:30 a.m.

 

Location:

Chateau on the Lake
415 North State Highway 265
Branson, MO 65616
Phone: (417) 334-1161 or (888) 333-LAKE

 

Detailed directions and maps from the Chateau on the Lake website

 

Travel and Directions:

Please make your own accommodations. SEL has procured a rate at the Chateau for this event of $129 per night for single or double occupancy. To secure the discounted rate, mention that you are with the Schweitzer Engineering Laboratories group when making your reservation. Make your reservations before July 28 to ensure this rate.


Agenda

Conference registration deadline: August 1, 2008

When registering, please choose one morning and one afternoon session to attend on Tuesday and Wednesday.


Seminar presentations will be provided ONLY in CD format. We invite you to bring your laptop for access to presentation materials during the T&D and General Sessions. Laptops are required for the hands-on sessions.

Tuesday, August 26

7:30 – 11:30 a.m.

checkbox

Advanced Transformer Protection

  • Harmonic Blocking vs. Harmonic Restraint
  • Restricted Earth Fault
  • Event Report Analysis Examples
checkbox

IEC 61850 and SEL-2411 RTU Replacement

  • IEC 61850 Overview
  • SEL-2411 Overview
  • ACSELERATOR® Architect® Software Overview
  • Demonstration Using GOOSE Messaging Between SEL-2411s to Replace Distributed RTUs
checkbox

New SEL Relay User Hands-On Session (laptop required)

12:30 4:00 p.m.

checkbox

Question and Answer Session for Technicians
(Submit no less than three questions when registering)

checkbox

Transmission Line Protection

  • Distance Element Improvements Case Study
  • Distance Element Performance Under Conditions of CT Saturation
  • Out of Step Relaying Solutions and Testing
  • Bonus: Event Report Analysis on Selected Transmission System Faults
checkbox
SEL Software Hands-On Session (laptop required)

Tuesday, August 26 • 7:30 a.m. – 4:00 p.m. (All Day Session)

checkbox

Automation Hands-On Using DNP LAN/WAN Protocol (laptop required)

  • DNP/TCP, SEL-3332, and SEL-2411 Overview
  • Configuring the SEL-3332 DNP/TCP (Hands-On)
  • Configuring the SEL-2411 DNP/TCP (Hands-On)

Wednesday, August 27

7:30 – 11:30 a.m.

checkbox

Bus Protection Tutorial

  • Fast Bus Trip Schemes
  • Using Transformer Relays for Bus Protection
  • Using the SEL-587Z High-Impedance and SEL-487B Low-Impedance Bus Relays
checkbox

NERC/CIP and SEL Solutions

  • Investigation Into the NERC CIP Requirements
  • Practical Approach to Achieving Security and Compliance
  • Taking the Scare Out of Cryptology
  • Low- or No-Cost Cybersecurity Solutions

12:30 4:00 p.m.

checkbox

Generator Protection

  • SEL-300G Capabilities
  • Connections to Relay
  • Protection for a Small Unit
  • Protective Function Settings
  • Post-Operation Analysis

Utility/Industrial Intertie

  • Application Guide 2002-17
  • SEL-351 Capabilities
  • Over/Undervoltage and Over/Underfrequency
  • Synchronism Check
  • Reverse Power
  • Directional Overcurrent
checkbox

Event Report Analysis and Commissioning Protection Systems

  • Importance of Relay and Programmable Logic Documentation
  • Commissioning of Protective Relay Systems
  • Analysis of Selected Event Reports – Could Proper Documentation and Commissioning Have Prevented These Events?

Wednesday, August 27 • 7:30 a.m. – 4:00 p.m. (All Day Sessions)

checkbox
Protection Hands-On for Transformer Differential Relays (laptop required)
checkbox

Automation Hands-On Using DNP LAN/WAN Protocol (laptop required)

  • DNP/TCP, SEL-3332, and SEL-2411 Overview
  • Configuring the SEL-3332 DNP/TCP (Hands-On)
  • Configuring the SEL-2411 DNP/TCP (Hands-On)

Thursday, August 28

7:30 – 11:30 a.m.

checkbox

Technical Seminar

  • New Products and Company Update
  • Distribution Automation Solutions
  • SEL-3378 Synchrophasor Vector Processor
  • And more!

 

 

 

Register Today!

Making Electric Power Safer, More Reliable, and More Economical
Schweitzer Engineering Labs
2350 NE Hopkins Court - Pullman, WA 99163 – USA
Phone: +1.509.332.1890 - Fax: +1.509.332.7990