- Simple,
Complete Integration
Link all substation intelligent electronic devices (IEDs) into a single,
low-cost configurable contact point for SCADA, local human-machine interface
(HMI), dial-in access, dial-out notification, and overall substation integration
applications. Link multiple communications processors to provide redundant
communications paths when necessary.
- Sequential
Events Recorder (SER) Functions
Receives SER messages from SEL devices and updates
local SER database. Monitors optional contact inputs,
time-tags transitions, and saves SER records. Sends SER
records to host using DNP3 LAN/WAN and SEL Fast SER messages.
- Two
Plug-In Protocol-Processor Card Slots Support SEL-2700
Series Cards
Provides communication on hardware-specific local area networks. The SEL-2711
Modbus Plus Protocol Card® connects with Modbus Plus networks. The SEL-2701
Ethernet Processor interfaces with fiber and copper Ethernet networks
and includes support for Telnet, FTP, DNP3 LAN/WAN, IEC 61850/UCA2, and the OSI, TCP, and UDP stacks.
- Automatic
Database
Collect, store, and forward meter reports, targets, digital input status,
event reports, demand meter reports, and more. Use the optional Flash memory
for nonvolatile storage.
- Modbus
Slave, DNP3 Level 2 Slave, and ASCII Serial Protocols
Provides easy-to-configure support for these popular serial protocols. SCADA
links, local HMI, and dial-in modems can access data from multiple IEDs or
communicate directly with individual IEDs.
- Programmable
Logic Controller (PLC) Functions
Use Boolean and arithmetic operators and IF-THEN ELSE SELOGIC® statements
to create logical schemes to produce and forward information or perform control.
Reduce overall system costs and improve system reliability by reducing the
number of auxiliary devices.
|
Version
R110 of the SEL-2032 Communications Processor firmware
released in January 2008. View
SEL-2032 Version Announcement
- Sixteen
additional optoisolated inputs and four programmable
output contacts.
- SEL-2701
Ethernet Processor.
- SEL-2711
Modbus Plus Protocol Card.
- Conformal Coating—Protect equipment from harsh environments and airborne contaminants such as hydrogen sulfide, chlorine, salt, and moisture.
Learn more about conformal coating.

- Use plug-in cards in
the SEL-2032 to connect IEDs to Ethernet or Modbus Plus networks.
- Eliminate or reduce
the need for SCADA RTUs.
- Simplify, improve the
reliability, and reduce the total cost of SCADA systems by using the SEL-2032
to collect and scale meter data, and also to collect targets, contact input
status, and fault location directly from relays. Use the contact outputs
of relays and other IEDs for control. Directly support Modbus RTU Slave
and DNP3 Level 2 protocols for links to RTUs or masters.
- Connect IEDs that do
not support Modbus to a distributed control system (DCS). The communications
processor provides faster updates to the DCS than would a multidrop system
because it groups data for more efficient multiple-register or block access.
Arithmetic functions can change scaling, calculate virtual analog inputs,
and compare analog values to thresholds. Use SELOGIC control
equations to combine digital inputs to initiate and qualify automatic control,
or for interlocks.
- Support local HMI on
a PC or industrial computer using the SEL-2032 as a communications hub
for gathering data from and directing control commands to IEDs in the substation.
Local event report collection, settings management, and data archiving
may also be included in the local HMI.
- Set the communications
processor to detect critical conditions and dial a pager. Send an ASCII
message to an alphanumeric pager or an SEL-3010
Event Messenger.
- Use the SEL-2032 as
a hub to enable low-cost, point-to-point fiber-optic
links that isolate equipment from hazardous and damaging ground potential
rise; eliminate RFI, EMI, and communications system ground loops; and allow
longer signal paths than possible with EIA-232 copper connections.
- Acquire and forward
information from relays and specialized equipment monitoring devices to
maintenance databases and expert systems.
- Use SEL-5020
Settings Assistant Software to prepare settings and communicate with
the communications processor.
- Use with SEL-5040
Power System Report Manager Software to automatically gather relay
event reports and manage them with a database.

Budgetary
Retail, Quantity 1: $4,310
(Prices
displayed are for planning purposes and are
subject to change. Contact your SEL
sales representative today for a quote
on configurations and quantities to meet your
needs.)

|