 The SEL-2414 Transformer Monitor provides an exceptional combination of monitoring, control, and communications in a compact package.
High Reliability and Rugged Design
Built to the same high standards as SEL protective relays, the SEL-2414 withstands vibration, electrical surges, fast transients, and extreme temperatures, meeting stringent industry standards. Compare our specification compliance, higher reliability, price, and worldwide, ten-year warranty to other transformer monitors.
Flexible I/O for Local Control and System Applications
Choose input/output options that include digital inputs for status, such as oil level and sudden pressure; RTD inputs for such measurements as ambient, top-oil, and hot-spot temperatures; digital outputs for control and alarms; analog inputs and outputs; and ac current and voltage inputs.
Easily program monitoring and control functions with powerful logic, math, timers, counters, and edge-trigger functions. These features allow easy integration with new and retrofit transformer monitor applications.
Critical Reporting and Logging
Store up to 512 Sequential Events Recorder (SER) reports of digital input transitions, time-tagged to the nearest millisecond. Analyze SER reports, analog trending, and oscillographic event reports for rapid commissioning, testing, and post-event diagnostics. Send the SER data to a communications processor or computer for system analysis.
Communications and Integration
Automate fan bank control with flexible communications options that provide easy integration with SCADA. Choose from Ethernet, Modbus® TCP, DNP3 LAN/WAN, IEC 61850, Telnet, FTP, Modbus Serial, EIA-232, EIA-485, and DNP3 RTU protocols.
AC Metering Capabilities
Measure and record voltage, current, power, energy, power factor, and frequency; demand/peak demand metering; and maximum/minimum metering with extensive ac metering and monitoring capabilities. Apply values in programmable calculations and triggers within the meter.
Simple Commissioning Tools
Easily set with ACSELERATOR QuickSet® SEL-5030 Software. Front-panel HMI provides complete configuration access and displays settings, measurements, and calculated values.
 Apply flexible I/O options to meet the many needs of new or retrofit transformer installations. Use digital inputs (DI) to monitor critical transformer alarms and status points. Use analog inputs (AI) to measure pressure, oil level, temperatures, tap positions, and process-level signals from transducers. Operate cooling fans and alarms, or provide indication with digital outputs (DO) and analog outputs (AO).

Budgetary Retail, Quantity 1: $1520
(Prices displayed are for planning purposes and
are subject to change. Contact your SEL
sales representative today for a quote on configurations
and quantities to meet your needs.)

Select from a wide variety of optional interface cards, temperature monitors, mounting kits and time and communication options for your SEL-2414. More information is available here.
|