Literature Careers Products Services Contact Home Home
Products for Protection, Monitoring, Control, Automation, and Metering


SEL-2505

Remote I/O Module

Expand available device inputs and outputs, add MIRRORED BITS® communications to non-MIRRORED BITS devices.

SEL-2505 Remote I/O Module
UL CSA CE

  • Protection and Monitoring
    Add simple bus protection using contact inputs and outputs from existing relays. Add secure pilot communications to existing two- and three-terminal line applications. Add local or remote trip and close coil monitoring capability.
  • Integration
    Expand the I/O of SEL relays that are MIRRORED BITS compatible without modification to the control panel face. Make I/O status from any relay available to SEL MIRRORED BITS schemes.
  • Safety
    Replace control wiring to outside cabinets with fiber-optic cable to reduce dc ground exposure.
  • Dependability
    Use the communication monitoring feature to alarm when fiber-optic control cabling has been damaged, disturbed, or altered.
  • Savings
    Reduce project costs by using two fibers instead of 32 large diameter wires, with less material expense, reduced trench and raceway requirements, and less labor for design, documentation, installation, testing, and maintenance.

 

  • The base-model SEL-2505 is configured with an on-board V-pin fiber-optic transceiver/modem. To receive the unit with an on-board ST-type connection, this option must be selected when ordering.

 

  • Inexpensively extend contact I/O on SEL relays that are MIRRORED BITS communications compatible
  • Add MIRRORED BITS communications to any protective relay (numeric or electromechanical) or other IED.
  • Connect two SEL-2505s together to share digital contact I/O information between any two IEDs.
  • Monitor data channel integrity to increase protection scheme or I/O security above that of traditional systems.
  • Create simple bus protection using existing line relay contact I/O and the SEL-2505.

 

Budgetary Retail, Quantity 1: $525
Fully Optioned Price: $1,575
(Prices displayed are for planning purposes and are subject to change. Contact your SEL sales representative today for a quote on configurations and quantities to meet your needs.)

Wiring saved by fiber

Reduce project costs by using two fibers instead of 32 large-diameter wires, with less  material expense, reduced trench and raceway requirements, and less labor for design, documentation, installation, testing, and maintaining.

Get Adobe Reader Some of the following documents require the use of Adobe® Reader.®
 Get the free reader here.

Datasheets

 

Model Option Tables

 

Product Flyers

 

Instruction Manual

 

Technical Papers

drawings

Front View
Side View
Bottom View
Dimension Drawings

Making Electric Power Safer, More Reliable, and More Economical
Schweitzer Engineering Labs
2350 NE Hopkins Court - Pullman, WA 99163 – USA
Phone: +1.509.332.1890 - Fax: +1.509.332.7990