- Dependable
Overcurrent Protection
Six levels of phase, negative-sequence, neutral, and
residual overcurrent elements for coordinated protection,
along with phase and sequence under- and overvoltage
elements to maximize control scheme flexibility.
- Enhanced
Security
Voltage or load-encroachment control of the four phase
time-overcurrent elements for load security.
- Innovative
Directional Elements
Positive-sequence voltage-polarized phase directional
element with memory for directional stability during
phase faults.
Best Choice Ground Directional Element System logic
for secure ground directional element operation for all
types of system grounding practices under varying system
conditions.
- Under-
/ Overfrequency Protection
Up to six steps of accurate frequency elements for multilevel
under- and overfrequency trip and control.
- Reclosing
Control
Programmable four-shot recloser with optional synchronism check
to match a variety of reclosing practices.
- Metering
Accurate metering eliminates the need for external meters
(MW, MVAR, MWh, MVARh, PF, instantaneous/peak demand).
- Input
Voltage Settings
Select line-neutral (WYE) or line-line (delta) input
AC voltage connections using software settings.
- ACSELERATOR® QuickSet Software
Helps speed relay application by allowing you to develop
relay settings off-line, program SELOGIC® control
equations, and analyze post-fault event reports.

| SEL-351A Version |
Standard
SEL-351A |
Nondirectional,
Three Voltage Input
SEL-351A1 |
| SELOGIC® Control Equations |
Yes |
Yes |
| Event Report |
Yes |
Yes |
| Sequential Events Recorder (SER) |
Yes |
Yes |
| Breaker Wear Monitor |
Yes |
Yes |
| Station Battery Monitor |
Yes |
No |
| DNP3 Level 2 Slave |
Yes** |
Yes** |
| High-Accuracy Metering |
Yes |
Yes |
| Remote and Local Control Switches |
Yes** |
Yes |
| Wye or Delta Voltage Connection |
Yes |
Yes |
| Synchrophasor Measurements |
Yes |
Yes |
| Fault Locator |
Yes |
Yes |
| Fast SER Protocol |
Yes |
Yes |
| Sensitive Earth Fault Protection |
Yes** |
No |
| Directional Protection |
Yes |
No |
| Two Residual Ground Time-Overcurrent Elements |
Yes |
No |
| Load-Encroachment Logic |
Yes |
No |
| Synchronism Check |
Yes |
No |
| ACSELERATOR® QuickSet™ Compatible |
Yes |
Yes |
| Conformal Coating |
Yes** |
Yes** |
** Ordering Option
|

- Provide
primary or backup overcurrent protection on distribution
systems with sensitive phase, negative-sequence, residual,
and neutral overcurrent protection elements.
- Use
wire-alike terminal configurations to take advantage
of advancing technology, improving system protection
performance, and reducing total costs. This is the
wire-alike upgrade for the popular SEL-251 Relay.
- Set
the sensitive phase and ground directional elements
for accurate and secure fault detection.
-
Enhance sensitivity with two independent residual ground time-overcurrent elements.
- Measure
and record in nonvolatile memory MW, MVAR, MWh, MVARh,
PF, instantaneous and/or peak demand, eliminating the
need for external meters.
- Provide
multi-step load shedding schemes using under- /overfrequency
elements.
- Send synchrophasor data to SCADA and wide-area measurement systems using SEL Fast Messages at rates of up to 60 times per minute. Accuracy of ±1 degree and microsecond timing of event reports improve system visualization and event analysis. Use SEL-5077 SYNCHROWAVE™ Server Software to time-correlate synchrophasor data from SEL-351A Relays and send it to display and archiving systems, such as SEL-5078 SYNCHROWAVE Console Software.


Budgetary
Retail, Quantity 1: $1,790
Fully Optioned Price: $2,765
(Prices
displayed are for planning purposes and are subject to
change. Contact your SEL sales representative today
for a quote on configurations and quantities to meet your
needs.)
* CE compliance for screw-terminal block version only |