- Maximize
the Capability of Substation Equipment
Fully
load equipment by monitoring power, including thermal
or rolling interval demand as well as peak demand on
positive-, negative-, and zero-sequence current. Use
the full capacity of the equipment while maintaining
SEL quality protection.
- Advanced Visualization Tools
The SEL-451 offers a configurable human-machine interface (HMI) to allow for easy integration into your application or operating standards. HMI tools include custom metering and status displays, direct pushbutton access, critical information alarms in chronological order, rotating display, and timestamped sequential events recorder (SER) report.
- Bay
Control for Two Breakers
Complete two-breaker control and breaker failure complement
the versatility of the SEL-451 programmable logic to
meet your bay control needs. Easily control motor-operated
switches, capacitor banks, and field I/O from the front
panel or remotely. Use configurable labels to customize
relay controls to match your application.
- Communications
Download event reports in seconds, instead of minutes,
using the optional Ethernet port with
Telnet and FTP. Quickly move information with DNP3 LAN/WAN or IEC 61850 protocols.
- Improve Operation With IEEE Synchrophasor Data
Give operators critical system information via serial or Ethernet communications. Install required substation protection, monitoring, and control using the SEL-451, and get a built-in phasor measurement unit at each substation.
- High-Accuracy
Timestamping
Time-tag binary COMTRADE event reports with real-time
accuracy of better than 10 µs. View system state
information at time of faults, or with timed triggers,
across the entire system. Use system state information
to validate system models and improve transfer limits
and system stability.
- Digital
Fault Recording
Combine relaying reliability with true DFR functionality.
The SEL-451 Relay's high-speed sampling (8 kHz) and
COMTRADE output provide advanced oscillography. Use
the ACSELERATOR® QuickSet SEL-5030
Software graphical user interface for harmonic analysis
and easy event viewing.
- Integrate Many Substation Devices Into One Powerful System Using the SEL-451.
Control cooling fans, motor-operated switches, or other equipment using the processing and I/O of the SEL-451. Hardware options let you expand I/O to 55 inputs and 24 outputs.
- Expanded
SELOGIC® Control
Equations
Use math and logic combinations of analog and digital
values for customized applications. Adapt system control
based on prefault conditions. Scale analog values and
latch momentary inputs for SCADA retrieval.
- ACSELERATOR QuickSet
Software
Help speed relay applications by developing relay settings
offline, programming SELOGIC control
equations, and analyzing post-fault event reports.
|

- Rack-
or panel-mount, horizontal and vertical hardware packages.
- Ethernet connection options for primary and standby connections
- 10/100BASE-T
- 10BASE-FL
- 100BASE-FX
- DNP3
Level 2 Slave communications protocol.
- One
or two additional I/O boards with standard, high-interrupting
or high-speed/high-interrupting outputs.
- User-configurable labels for operator controls and target
LEDs.
- Connectorized® hardware
configuration.
- Enhanced HMI with 24 target LEDs and 12 operator pushbuttons.
- Independent breaker trip/close pushbuttons with status indication, including 24 additional input and 4 additional output contacts.
- High-impedance fault detection using Arc Sense™ technology.
- Conformal Coating—Protect equipment from harsh environments and airborne contaminants such as hydrogen sulfide, chlorine, salt, and moisture.
Learn more about conformal coating.

- Apply
overcurrent protection for primary and backup, and
three-pole tripping schemes on subtransmission lines.
- Make
settings for up to four shots of automatic breaker
reclosing for one or two circuit breakers, with synchronism
and voltage checks to optimize system restoration.
- Use
the built-in fault locator to efficiently dispatch
line inspection and repair personnel.
- Operate
power systems with maximum stable loading using real-time
voltage and current synchrophasors.
- Implement
breaker failure logic for one or two circuit breakers.
- Schedule
as-needed circuit breaker maintenance and send alarms
when the breaker monitor detects excess breaker contact
wear.
- Track
average and last circuit breaker operating time.
Alarm on slow circuit breaker.
- Alarm
for low-voltage conditions on one or two station
batteries.
- Use SEL-5601 Analytic Assistant Software to
display oscillograms and vector diagrams to analyze
event reports.
- Detect downed conductors and high-impedance faults with patent-pending Arc Sense technology.


|
SEL accessories simplify operation and enhance the flexibility of SEL products. |
Add independent breaker control to any relay. The SEL-9510 Control Switch Module easily installs in panel or rack locations for independent local control and status indications.

|

Budgetary
Retail, Quantity 1: $4,200
Fully Optioned Price: $9,960
(Prices
displayed are for planning purposes and are subject to
change. Contact your SEL
sales representative today for a quote on configurations
and quantities to meet your needs.)

|